Description
Study and operate a continuous flash evaporation process under reduced pressure
Study of the control loops
- Pressure
- Vacuum
- Flow rate
- Level and temperature
Study of the different technologies used
Operate the evaporation process on an aqueous product
- Start‐up and warm up procedure
- Monitor production and analyses material and thermal balance
- Quality control by monitoring product density
General Specifications
- 60 L polyethylene feeding tank.
- Stainless steel centrifugal pump
- Stainless steel mono-tube pre-heater.
- Evaporator, glass, ND 100, stainless steel condenser.
- Shell and tube condenser.
- Graduated glass receiver, 2L.
- Stainless steel centrifugal pump, by-pass
- Overheating exchanger
- Cooling exchanger for steam condensate.
- Graduated glass receiver, 2L.
- Stainless steel centrifugal pump, draining valve.
- Water circuitry.
- Vacuum circuitry.
- Steam circuit.
Instrumentation
- Nine Pt100Ω temperature probes.
- Two manometers: 0/ 4 bar and -1/0 bar.
- Two absolute pressure transmitters: 0-2 bar and 0-2.5 bar.
- A relative pressure transmitters: 0-2 bar.
- A differential pressure transmitters: 0-100mbar.
- A level capacitive sensor.
- A level ultrasonic sensor.
- A float flowmeter: 40 to 400 L/h.
- A gear flowmeter: 0.5 to 50 L/h.
- A magnetic flow meter: 100 to 1000 L/h.