Description
Separation industrial process implementation
Continuous distillation study under atmospheric pressure
Process operation training
- Unit start-up
- Determination of an operating point
- Controls configuration
- Transitory phase study
- Study of the different types of control: level, temperature, flow, pressure
Influence of the operating parameters
- Heating power
- Feed rate
- Feeding solution concentration
- Reflux ratio
Perform a continuous process:
- Mass and thermal balance
- Yield
General Specifications
- 30L polyethylene tank. Draining valve.
- 2 gear pumps SS/PEEK head, with integrated safety valve.
- SS preheater.
- 6L max. glass thermosiphon boiler, SS heating element.
- Glass column, removable insulating, glass bubble cap trays, SS intermediary trays.
- Glass condenser, SS coil.
- Glass refrigerant, sampling valve.
- 2 graduated glass vessels, solenoid valve.
- 2 polyethylene tank, 10L.
- Cold water circuit.
- SS spill containment tray, draining valve.
Safety
– Venting thermostate.
– Pressure relief on the heating line.
Instrumentation
- Temperature probes Pt 100Ω.
- 1 safety thermostat.
- 1 vane flow transmitter.
- 1 water flow transmitter.
- 1 ethanol flow transmitter.
- 3 electronic relative pressure transmitters.
- 1 electronic differential pressure transmitter.
- 3 level detectors.
Dim : 230 x 175 x 300 cm – 500 kg
SS tubular framework 40 x 40mm
For a complete product data sheet and a list of reference sites please call 1-877-967-2726.