Description
The 4-20mA signals available on wiring terminals Ø 4mm
- Alimentation possible from the flow control bench
- Unit can be put on table
Study and adjust a level control loop.
Study and adjust sensors and actuators.
Study and adjust a simple control loop:
- Identify loop components: sensor, controller, actuator
- Controlling variable and controlled variable concepts
- Identify the system: integration constant and dead time
- Determine P, I and D actions and controller parameters
- Study the system̍s response to interference and set point changes
Use a technical industrial file.
General Specifications
- Control valve SS core Masoneilan Varipack with variable Cv.
- Pneumatic actuator and positioner.
- Cylindrical PVC transparent graduated tank.
- Internal overflow tube with 2 different sections linear zones.
- Interference piping.
- Compressed air feeding circuit : pressure reducing gauge.
Instrumentation
- Relative pressure transmitter : 0 to 60 mbar for hydrostatic level measurement.
- PID configurable controller.
Dim : 80 x 60 x 80cm – 50 kg
Aluminum profile framework 30 x 30mm
For a complete product data sheet and a list of reference sites please call 1-877-967-2726.