Wireless O2 (Oxygen) Sensor

Product Code: PS-3217

Description

The Wireless Oxygen Gas Sensor measures gaseous O2 concentration as well as humidity and air temperature for a range of biology, environmental science, and physiology activities.

The Wireless Oxygen Gas Sensor is accurate and easy to use, making it the perfect sensor for studying photosynthesis, respiration, and oxygen cycling in a closed or open system. With remote logging, experiments can go beyond the lab period and easily give students hours or days of data for analysis. In addition to measuring oxygen gas levels, the Wireless Oxygen Gas Sensor also contains sensors to measure ambient temperature and humidity.


Features

  • Bluetooth® and USB connectivity
  • 0-100% Oxygen Gas Concentration
  • ±1% Oxygen at constant temperature and pressure
  • Also reports ambient temperature and humidity
  • 2-3 year operating life with replaceable sensing element

Experiment Library

Perform the following experiments and more with the Wireless Oxygen Gas Sensor.
Visit PASCO’s Experiment Library to view all activities for this product.


No need for an interface.

All PASCO Wireless Sensors connect to computers, Chromebooks, and tablets, through Bluetooth 4. No other equipment required! Our software (SPARKvue or PASCO Capstone) allows students to see and analyze data in real-time.


Long-lasting, rechargeable battery

The Wireless Oxygen Gas Sensor draws as little current as possible. This provides you with a long battery life for lab activities. Our software also displays the battery level at all times. If it dips too low, connect the USB cable to charge while you collect data.


Product Specifications

Range 0 to 100 % O2 concentration; 0 to 1,000,000 ppm
Resolution 0.01% oxygen
Repeatability 0.5% oxygen
Accuracy ±1% O2 at constant temp and pressure; ±5% O2 outside operating range
Operating temps 0 – 40°C
Relative humidity range 0 – 100% non-condensing
Sensing element lifespan 2+ years

Battery & Logging

Stored Data Points Memory (Logging) 1 >25,000
Battery – Connected (Data Collection Mode) 2 NA
Battery – Logging (Data Logging Mode) 3 10 days
Battery Type LiPo

1 Minimum # of data points with all measurements enabled, actual results depend on enabled measurements.

2 Continuous use in a connected state until battery failure, actual results will depend on sample rate, active measurements, and battery condition.

3 Logging until battery failure, actual results will depend on sample rate, active measurements, and battery condition.

* Normal classroom use is the sensor in active use for 20min/lab for 120 lab periods/yr.